• Shopping Cart Shopping Cart
    0Shopping Cart
TK Engineering Oy
  • Businesses
    • Defence
    • Energy
    • Marine
    • Off-Highway Vehicles
  • Services
    • Control system design
    • Testing & Troubleshooting
    • Research / Pre-Study
    • Product development
    • Training
  • IoE by TKE
    • Sensing Network
    • IoEX Gateway
    • Human as a Sensor
    • Analytics
  • Products
    • CANtrace
    • TKE Driver Training
    • CAN bus
    • Automation
    • Telematics
    • Manufactures
  • Articles
    • Case Studies
    • News
    • Research and publications
    • New products
  • Company
    • Cyber Security
    • Partners
    • Distributors
    • Careers
  • Contact us
  • Shop
  • Menu Menu

CANtrace Help

A powerful CAN bus analyser software and diagnostic tool

  • CANtrace features
  • Knowledge base
  • Get CANtrace

10. Tab Views

10.3 Data Tab

10.3 Data Tab

The Data tab displays the run time value of the signals (from an associated database) received from the connected/monitored CAN networks. The value can be displayed in many formats, e.g. Physical which is a human-readable format.

10.3.1 Data Tab UI

The figure and table below explain the user interface of the Data tab. By right-clicking on the window or selecting Data from the top menu, you will find three submenu items. Submenu item Clear Values will clear the current values of the signal. Submenu item Configure Signals will open the form for you to add/remove the signals in the data window. Submenu item Font allows selecting between two different font sizes: Normal and Large. The current selection is remembered when CANtrace is closed.

Figure 10.6 Signals view in the Data tab

Table 10.3 Data window column description

Column Name Column Description
Name By default, the “Name” is set to the Signal name, but it can be changed in the “Name” field within the “Configure Signals” dialog.
Physical Value To determine the signal value, the system first checks if a symbolic value exists in the signal’s value table. If a symbolic value is found, that value is used. If no symbolic value is available for the current signal value, the corresponding physical value is displayed instead. If a unit is available, it will be included with the physical value.
Raw value The configured signal’s current raw value is shown in the application’s number format setting, either Hexadecimal or Decimal.
Channel The software channel that the message containing this signal arrived on.

10.3.2 Configure Signals

Before adding a signal to the Data tab, the user needs to add a database first. Click here to see how to add a database.
To add, remove or configure signals, just right click the data window and choose Configure Signals from the menu. The Configure Signals window will appear, as shown below.

Figure 10.7 Configure Signals Dialog

Each added signal has its own configuration. When a signal is selected, its information from the database will be displayed on the right side of the window.

Signal Name: The original name of the signal as defined in the database.
Message Name: Shows the name of the parent message associated with the selected signal in the database.
Database: The name of the database of the signal.
Source Node: Indicates the name of the sourcenode for the signal.
Message Identifier: Message identifier for the signals message.
Channel: The software channel in CANtrace to which this database is assigned to.

Table 10.4 Configure Signals Form Description

Name Description
Add… Add signals from the associated database
Add from graph… Add the configured signals from the graph window if there are any
Delete Delete the chosen signals
Delete all Delete all the signals in the data window
Name Signal name that is editable. You can define your own name of the signal that will be shown in the data window Name column, e.g. if the signal name is EngineSpeed, you can define rpm as the name.
NOTE! Doesn’t change database This doesn’t change the original associated database file, it only changes the name shown on data window .
Data validity time: Determines how long a signal value is displayed in the data view after the signal is no longer present on the CAN bus.

Buttons:

OK – Saves and applies the configuration and closes the dialogue
Cancel – Discards the configuration and closes the dialogue
Help – Opens the Data Window section in the help document

Content

  • CANtrace 4.2
  • Imporant
  • Getting Started
  • Database
  • CastorUSB Settings
  • Vector Settings
  • Kvaser Settings
  • Peak Settings
  • Softing Settings
  • Play Log File Settings
  • Tab Views – Trace Tab
  • Tab Views – Send Tab
  • Tab Views – Data Tab
  • Tab Views – Graph Tab
  • Tab Views – Statistic Tab
  • Tab Views – CANopen NodeScanner Tab
  • Tab Views – Scripting Tab
  • Log Settings
  • Database Log Settings
  • Log File Description
  • License
  • CANopen
  • J1939
  • CAN FD
  • Logging with a Memorator
  • Acknowledgements

TK Engineering Oy

Hovioikeudenpuistikko 13 as 3
65100 Vaasa, Finland

Kauppakatu 3 B
33200 Tampere, Finland

info@tke.fi
Phone: +358 6 357 6300

Highest creditworthiness
© Copyright - TK Engineering Oy Privacy and cookies policy
Scroll to top